Most sold EVs in Sweden
November 2025 · Month
Below is the charging curve for Polestar 2 Standard Range Single Motor (GEN1), illustrating the charging speed at various battery levels. Additionally, graphs for range and time provide comprehensive details on charging performance.
| SOC Range | Charger output (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 24.2 kW | 2 h 31 m 1 s | 61.0 kWh |
| 10-100% | 24.0 kW | 2 h 17 m 18 s | 54.9 kWh |
| 10-80% | 77.5 kW | 33 m 3 s | 42.7 kWh |
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 2.9 km (1.8 mi) | ? | ? |
| 10-100% | ? | 2.9 km (1.8 mi) | ? | ? |
| 10-80% | ? | 9.3 km (5.8 mi) | ? | ? |
| SOC | Charger output | Total time from 0% | Energy into battery |
|---|---|---|---|
|
0 |
1 kW | 00:00:00 | 0 kWh |
|
1 |
12 kW | 00:05:58 | 0.6 kWh |
|
2 |
23 kW | 00:08:11 | 1.2 kWh |
|
3 |
34 kW | 00:09:33 | 1.8 kWh |
|
4 |
45 kW | 00:10:32 | 2.4 kWh |
|
5 |
56 kW | 00:11:18 | 3.0 kWh |
|
6 |
66 kW | 00:11:56 | 3.7 kWh |
|
7 |
77 kW | 00:12:28 | 4.3 kWh |
|
8 |
88 kW | 00:12:56 | 4.9 kWh |
|
9 |
99 kW | 00:13:21 | 5.5 kWh |
|
10 |
110 kW | 00:13:43 | 6.1 kWh |
|
11 |
110 kW | 00:14:04 | 6.7 kWh |
|
12 |
112 kW | 00:14:25 | 7.3 kWh |
|
13 |
113 kW | 00:14:45 | 7.9 kWh |
|
14 |
113 kW | 00:15:06 | 8.5 kWh |
|
15 |
113 kW | 00:15:26 | 9.2 kWh |
|
16 |
114 kW | 00:15:47 | 9.8 kWh |
|
17 |
114 kW | 00:16:07 | 10.4 kWh |
|
18 |
114 kW | 00:16:27 | 11.0 kWh |
|
19 |
114 kW | 00:16:47 | 11.6 kWh |
|
20 |
114 kW | 00:17:08 | 12.2 kWh |
|
21 |
114 kW | 00:17:28 | 12.8 kWh |
|
22 |
115 kW | 00:17:48 | 13.4 kWh |
|
23 |
115 kW | 00:18:08 | 14.0 kWh |
|
24 |
115 kW | 00:18:28 | 14.6 kWh |
|
25 |
115 kW | 00:18:49 | 15.2 kWh |
|
26 |
115 kW | 00:19:09 | 15.9 kWh |
|
27 |
115 kW | 00:19:29 | 16.5 kWh |
|
28 |
115 kW | 00:19:49 | 17.1 kWh |
|
29 |
115 kW | 00:20:09 | 17.7 kWh |
|
30 |
115 kW | 00:20:29 | 18.3 kWh |
|
31 |
116 kW | 00:20:49 | 18.9 kWh |
|
32 |
116 kW | 00:21:09 | 19.5 kWh |
|
33 |
116 kW | 00:21:29 | 20.1 kWh |
|
34 |
116 kW | 00:21:49 | 20.7 kWh |
|
35 |
116 kW | 00:22:09 | 21.4 kWh |
|
36 |
116 kW | 00:22:29 | 22.0 kWh |
|
37 |
117 kW | 00:22:49 | 22.6 kWh |
|
38 |
117 kW | 00:23:08 | 23.2 kWh |
|
39 |
117 kW | 00:23:28 | 23.8 kWh |
|
40 |
117 kW | 00:23:48 | 24.4 kWh |
|
41 |
93 kW | 00:24:10 | 25.0 kWh |
|
42 |
93 kW | 00:24:35 | 25.6 kWh |
|
43 |
94 kW | 00:24:59 | 26.2 kWh |
|
44 |
94 kW | 00:25:24 | 26.8 kWh |
|
45 |
94 kW | 00:25:49 | 27.4 kWh |
|
46 |
94 kW | 00:26:13 | 28.1 kWh |
|
47 |
94 kW | 00:26:38 | 28.7 kWh |
|
48 |
95 kW | 00:27:02 | 29.3 kWh |
|
49 |
95 kW | 00:27:27 | 29.9 kWh |
|
50 |
95 kW | 00:27:51 | 30.5 kWh |
|
51 |
95 kW | 00:28:15 | 31.1 kWh |
|
52 |
95 kW | 00:28:40 | 31.7 kWh |
|
53 |
67 kW | 00:29:08 | 32.3 kWh |
|
54 |
69 kW | 00:29:42 | 32.9 kWh |
|
55 |
69 kW | 00:30:16 | 33.6 kWh |
|
56 |
69 kW | 00:30:49 | 34.2 kWh |
|
57 |
69 kW | 00:31:23 | 34.8 kWh |
|
58 |
69 kW | 00:31:56 | 35.4 kWh |
|
59 |
69 kW | 00:32:30 | 36.0 kWh |
|
60 |
69 kW | 00:33:03 | 36.6 kWh |
|
61 |
70 kW | 00:33:36 | 37.2 kWh |
|
62 |
70 kW | 00:34:09 | 37.8 kWh |
|
63 |
60 kW | 00:34:45 | 38.4 kWh |
|
64 |
60 kW | 00:35:23 | 39.0 kWh |
|
65 |
61 kW | 00:36:02 | 39.6 kWh |
|
66 |
61 kW | 00:36:40 | 40.3 kWh |
|
67 |
61 kW | 00:37:17 | 40.9 kWh |
|
68 |
61 kW | 00:37:55 | 41.5 kWh |
|
69 |
55 kW | 00:38:35 | 42.1 kWh |
|
70 |
56 kW | 00:39:17 | 42.7 kWh |
|
71 |
57 kW | 00:39:58 | 43.3 kWh |
|
72 |
57 kW | 00:40:38 | 43.9 kWh |
|
73 |
57 kW | 00:41:19 | 44.5 kWh |
|
74 |
57 kW | 00:41:59 | 45.1 kWh |
|
75 |
47 kW | 00:42:44 | 45.8 kWh |
|
76 |
47 kW | 00:43:33 | 46.4 kWh |
|
77 |
48 kW | 00:44:22 | 47.0 kWh |
|
78 |
48 kW | 00:45:10 | 47.6 kWh |
|
79 |
48 kW | 00:45:58 | 48.2 kWh |
|
80 |
48 kW | 00:46:46 | 48.8 kWh |
|
81 |
48 kW | 00:47:34 | 49.4 kWh |
|
82 |
48 kW | 00:48:23 | 50.0 kWh |
|
83 |
26 kW | 00:49:25 | 50.6 kWh |
|
84 |
27 kW | 00:50:52 | 51.2 kWh |
|
85 |
27 kW | 00:52:18 | 51.8 kWh |
|
86 |
27 kW | 00:53:43 | 52.5 kWh |
|
87 |
27 kW | 00:55:09 | 53.1 kWh |
|
88 |
27 kW | 00:56:35 | 53.7 kWh |
|
89 |
27 kW | 00:58:00 | 54.3 kWh |
|
90 |
11 kW | 01:00:02 | 54.9 kWh |
|
91 |
10 kW | 01:03:42 | 55.5 kWh |
|
92 |
9 kW | 01:07:45 | 56.1 kWh |
|
93 |
8 kW | 01:12:17 | 56.7 kWh |
|
94 |
7 kW | 01:17:26 | 57.3 kWh |
|
95 |
6 kW | 01:23:21 | 58.0 kWh |
|
96 |
5 kW | 01:30:22 | 58.6 kWh |
|
97 |
4 kW | 01:38:55 | 59.2 kWh |
|
98 |
3 kW | 01:49:56 | 59.8 kWh |
|
99 |
2 kW | 02:05:20 | 60.4 kWh |
|
100 |
1 kW | 02:31:01 | 61.0 kWh |
Charger output is the power the charging station delivers. Energy into battery is what actually arrives: around 5% is lost to heat and conversion along the way, and charging times are calculated from that reduced figure. Dividing energy by time therefore gives a value roughly 5% below the charger output column. The 5% is an estimate — real loss varies with temperature, state of charge and the charger used. Read more about charging loss
November 2025 · Month