Renault Scenic E-Tech electric High Range charging curve & performance

Here you find the charging curve for Renault Scenic E-Tech electric High Range.

Charge curve Full screen

Average charging speed 0 - 100%82,4 kW
Average charging speed 10-100%82,0 kW
Average charging speed 10-80%107,2 kW
Optimum charging area6% - 59%
Optimum charging speed included 5 minutes loss97,7kW
Optimum charge stop time28m18s

The above charging curve is at optimum conditions. However, cold or hot temperatures can significantly affect the curve. This curve also is based on starting charging on a low state of charge. Therefore, plugin in at a higher level can affect the curve positively or negatively. Read more about what affects charging speed in our charging article.

Renault Scenic E-Tech electric High Range have battery heating, making charging at an optimum battery temperature easier.

SOCSPEEDChargetimeChargetime totalEnergy charged
0%50 kW0 s0 m 0 s0 kWh
1%81 kW50 s0 m 50 s0,87 kWh
2%82 kW40 s1 m 30 s1,74 kWh
3%82 kW40 s2 m 10 s2,61 kWh
4%83 kW39 s2 m 50 s3,48 kWh
5%80 kW40 s3 m 31 s4,35 kWh
6%81 kW40 s4 m 12 s5,22 kWh
7%125 kW32 s4 m 44 s6,09 kWh
8%126 kW26 s5 m 10 s6,96 kWh
9%126 kW26 s5 m 36 s7,83 kWh
10%126 kW26 s6 m 2 s8,70 kWh
11%127 kW26 s6 m 29 s9,57 kWh
12%127 kW25 s6 m 54 s10,44 kWh
13%126 kW26 s7 m 21 s11,31 kWh
14%127 kW26 s7 m 47 s12,18 kWh
15%127 kW25 s8 m 13 s13,05 kWh
16%127 kW25 s8 m 39 s13,92 kWh
17%128 kW25 s9 m 4 s14,79 kWh
18%129 kW25 s9 m 30 s15,66 kWh
19%129 kW25 s9 m 56 s16,53 kWh
20%129 kW25 s10 m 21 s17,40 kWh
21%129 kW25 s10 m 47 s18,27 kWh
22%129 kW25 s11 m 12 s19,14 kWh
23%129 kW25 s11 m 38 s20,01 kWh
24%129 kW25 s12 m 3 s20,88 kWh
25%129 kW25 s12 m 29 s21,75 kWh
26%129 kW25 s12 m 55 s22,62 kWh
27%129 kW25 s13 m 20 s23,49 kWh
28%129 kW25 s13 m 46 s24,36 kWh
29%130 kW25 s14 m 11 s25,23 kWh
30%130 kW25 s14 m 36 s26,10 kWh
31%130 kW25 s15 m 2 s26,97 kWh
32%130 kW25 s15 m 27 s27,84 kWh
33%130 kW25 s15 m 53 s28,71 kWh
34%130 kW25 s16 m 18 s29,58 kWh
35%130 kW25 s16 m 43 s30,45 kWh
36%130 kW25 s17 m 9 s31,32 kWh
37%130 kW25 s17 m 34 s32,19 kWh
38%130 kW25 s17 m 59 s33,06 kWh
39%130 kW25 s18 m 25 s33,93 kWh
40%130 kW25 s18 m 50 s34,80 kWh
41%131 kW25 s19 m 15 s35,67 kWh
42%132 kW25 s19 m 40 s36,54 kWh
43%131 kW25 s20 m 5 s37,41 kWh
44%130 kW25 s20 m 31 s38,28 kWh
45%130 kW25 s20 m 56 s39,15 kWh
46%130 kW25 s21 m 21 s40,02 kWh
47%127 kW25 s21 m 47 s40,89 kWh
48%127 kW25 s22 m 13 s41,76 kWh
49%126 kW26 s22 m 39 s42,63 kWh
50%126 kW26 s23 m 5 s43,50 kWh
51%124 kW26 s23 m 32 s44,37 kWh
52%114 kW27 s23 m 59 s45,24 kWh
53%114 kW28 s24 m 28 s46,11 kWh
54%111 kW29 s24 m 58 s46,98 kWh
55%110 kW29 s25 m 27 s47,85 kWh
56%109 kW30 s25 m 58 s48,72 kWh
57%108 kW30 s26 m 28 s49,59 kWh
58%107 kW30 s26 m 59 s50,46 kWh
59%102 kW31 s27 m 30 s51,33 kWh
60%102 kW32 s28 m 2 s52,20 kWh
61%101 kW32 s28 m 35 s53,07 kWh
62%101 kW32 s29 m 8 s53,94 kWh
63%99 kW32 s29 m 41 s54,81 kWh
64%98 kW33 s30 m 14 s55,68 kWh
65%95 kW34 s30 m 48 s56,55 kWh
66%93 kW35 s31 m 23 s57,42 kWh
67%92 kW35 s31 m 59 s58,29 kWh
68%91 kW36 s32 m 35 s59,16 kWh
69%93 kW35 s33 m 11 s60,03 kWh
70%92 kW35 s33 m 46 s60,90 kWh
71%90 kW36 s34 m 23 s61,77 kWh
72%89 kW36 s34 m 59 s62,64 kWh
73%88 kW37 s35 m 37 s63,51 kWh
74%88 kW37 s36 m 14 s64,38 kWh
75%87 kW37 s36 m 52 s65,25 kWh
76%86 kW38 s37 m 30 s66,12 kWh
77%85 kW38 s38 m 9 s66,99 kWh
78%84 kW39 s38 m 48 s67,86 kWh
79%83 kW39 s39 m 27 s68,73 kWh
80%81 kW40 s40 m 7 s69,60 kWh
81%80 kW40 s40 m 48 s70,47 kWh
82%80 kW41 s41 m 29 s71,34 kWh
83%77 kW41 s42 m 11 s72,21 kWh
84%76 kW43 s42 m 54 s73,08 kWh
85%74 kW43 s43 m 38 s73,95 kWh
86%73 kW44 s44 m 23 s74,82 kWh
87%71 kW45 s45 m 9 s75,69 kWh
88%70 kW46 s45 m 56 s76,56 kWh
89%67 kW48 s46 m 44 s77,43 kWh
90%66 kW49 s47 m 34 s78,30 kWh
91%55 kW54 s48 m 28 s79,17 kWh
92%52 kW1 m 1 s49 m 30 s80,04 kWh
93%52 kW1 m 3 s50 m 33 s80,91 kWh
94%45 kW1 m 7 s51 m 41 s81,78 kWh
95%44 kW1 m 14 s52 m 55 s82,65 kWh
96%44 kW1 m 14 s54 m 10 s83,52 kWh
97%34 kW1 m 24 s55 m 35 s84,39 kWh
98%27 kW1 m 48 s57 m 23 s85,26 kWh
99%27 kW2 m 2 s59 m 25 s86,13 kWh
100%1 kW3 m 55 s1 h 3 m 20 s87,00 kWh