Renault 4 E-Tech 52kWh 150hp laadcurve & prestaties
Laatst gewijzigd: dec 30, 2025Hieronder staat de laadcurve voor Renault 4 E-Tech 52kWh 150hp, die de laadsnelheid bij verschillende batterijniveaus illustreert. Daarnaast bieden grafieken voor actieradius en tijd uitgebreide details over de laadprestaties.
Charging Highlights
Peak DC Speed
100 kW
Battery Capacity
55,0 kWh
Architecture
352 V
55,0 kWh —
Charging Performance
Average 0-100%
44,7 kW
Average 10-100%
43,5 kW
Average 10-80%
73,6 kW
Advanced Metrics
Max C-Rating
1,82C
Avg C-Rating
1,25C
Optimum Zone
5% – 57%
Time Analysis
Range Analysis
Key Insights
Optimum Speed
67,6 kW
Optimum Time
23m 59s
10-80% Time
29 m 39 s
Charging Speed Analysis
| SOC Range | Avg Speed (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 44,7 kW | 1 h 9 m 52 s | 52,0 kWh |
| 10-100% | 43,5 kW | 1 h 4 m 31 s | 46,8 kWh |
| 10-80% ⭐ | 73,6 kW | 29 m 39 s | 36,4 kWh |
Range Added Per Minute by Driving Cycle
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 5,9 km (3,7 mi) | ? | 3,7 km (2,3 mi) |
| 10-100% | ? | 5,7 km (3,5 mi) | ? | 3,6 km (2,2 mi) |
| 10-80% ⭐ | ? | 9,7 km (6,0 mi) | ? | 6,2 km (3,9 mi) |
Complete Charging Curve Data (0–100% SOC)
| SoC | Snelheid | Tijd | Opgeladen energie |
|---|---|---|---|
| 0% | 30 kW | 00:00:00 | 0 kWh |
| 1% | 40 kW | 00:00:57 | 0,5 kWh |
| 2% | 50 kW | 00:01:42 | 1,0 kWh |
| 3% | 60 kW | 00:02:18 | 1,6 kWh |
| 4% | 67 kW | 00:02:50 | 2,1 kWh |
| 5% | 73 kW | 00:03:19 | 2,6 kWh |
| 6% | 80 kW | 00:03:45 | 3,1 kWh |
| 7% | 82 kW | 00:04:10 | 3,6 kWh |
| 8% | 85 kW | 00:04:34 | 4,2 kWh |
| 9% | 88 kW | 00:04:57 | 4,7 kWh |
|
10 |
90 kW | 00:05:20 | 5,2 kWh |
|
11 |
92 kW | 00:05:42 | 5,7 kWh |
|
12 |
94 kW | 00:06:04 | 6,2 kWh |
|
13 |
96 kW | 00:06:25 | 6,8 kWh |
|
14 |
98 kW | 00:06:46 | 7,3 kWh |
|
15 |
100 kW | 00:07:06 | 7,8 kWh |
|
16 |
100 kW | 00:07:26 | 8,3 kWh |
|
17 |
100 kW | 00:07:46 | 8,8 kWh |
|
18 |
100 kW | 00:08:06 | 9,4 kWh |
|
19 |
100 kW | 00:08:27 | 9,9 kWh |
|
20 |
100 kW | 00:08:47 | 10,4 kWh |
|
21 |
100 kW | 00:09:07 | 10,9 kWh |
|
22 |
100 kW | 00:09:27 | 11,4 kWh |
|
23 |
100 kW | 00:09:47 | 12,0 kWh |
|
24 |
100 kW | 00:10:07 | 12,5 kWh |
|
25 |
100 kW | 00:10:27 | 13,0 kWh |
|
26 |
100 kW | 00:10:47 | 13,5 kWh |
|
27 |
100 kW | 00:11:08 | 14,0 kWh |
|
28 |
100 kW | 00:11:28 | 14,6 kWh |
|
29 |
100 kW | 00:11:48 | 15,1 kWh |
|
30 |
100 kW | 00:12:08 | 15,6 kWh |
|
31 |
100 kW | 00:12:28 | 16,1 kWh |
|
32 |
100 kW | 00:12:48 | 16,6 kWh |
|
33 |
100 kW | 00:13:08 | 17,2 kWh |
|
34 |
100 kW | 00:13:28 | 17,7 kWh |
|
35 |
100 kW | 00:13:49 | 18,2 kWh |
|
36 |
100 kW | 00:14:09 | 18,7 kWh |
|
37 |
100 kW | 00:14:29 | 19,2 kWh |
|
38 |
100 kW | 00:14:49 | 19,8 kWh |
|
39 |
100 kW | 00:15:09 | 20,3 kWh |
|
40 |
100 kW | 00:15:29 | 20,8 kWh |
|
41 |
98 kW | 00:15:50 | 21,3 kWh |
|
42 |
96 kW | 00:16:10 | 21,8 kWh |
|
43 |
94 kW | 00:16:31 | 22,4 kWh |
|
44 |
92 kW | 00:16:53 | 22,9 kWh |
|
45 |
90 kW | 00:17:15 | 23,4 kWh |
|
46 |
88 kW | 00:17:38 | 23,9 kWh |
|
47 |
86 kW | 00:18:01 | 24,4 kWh |
|
48 |
84 kW | 00:18:25 | 25,0 kWh |
|
49 |
82 kW | 00:18:49 | 25,5 kWh |
|
50 |
80 kW | 00:19:14 | 26,0 kWh |
|
51 |
79 kW | 00:19:39 | 26,5 kWh |
|
52 |
78 kW | 00:20:05 | 27,0 kWh |
|
53 |
77 kW | 00:20:31 | 27,6 kWh |
|
54 |
76 kW | 00:20:57 | 28,1 kWh |
|
55 |
75 kW | 00:21:24 | 28,6 kWh |
|
56 |
74 kW | 00:21:51 | 29,1 kWh |
|
57 |
73 kW | 00:22:18 | 29,6 kWh |
|
58 |
72 kW | 00:22:46 | 30,2 kWh |
|
59 |
71 kW | 00:23:14 | 30,7 kWh |
|
60 |
70 kW | 00:23:43 | 31,2 kWh |
|
61 |
69 kW | 00:24:12 | 31,7 kWh |
|
62 |
68 kW | 00:24:41 | 32,2 kWh |
|
63 |
67 kW | 00:25:11 | 32,8 kWh |
|
64 |
66 kW | 00:25:41 | 33,3 kWh |
|
65 |
65 kW | 00:26:12 | 33,8 kWh |
|
66 |
64 kW | 00:26:43 | 34,3 kWh |
|
67 |
63 kW | 00:27:15 | 34,8 kWh |
|
68 |
62 kW | 00:27:47 | 35,4 kWh |
|
69 |
61 kW | 00:28:20 | 35,9 kWh |
|
70 |
60 kW | 00:28:53 | 36,4 kWh |
|
71 |
59 kW | 00:29:27 | 36,9 kWh |
|
72 |
58 kW | 00:30:01 | 37,4 kWh |
|
73 |
57 kW | 00:30:36 | 38,0 kWh |
|
74 |
56 kW | 00:31:12 | 38,5 kWh |
|
75 |
55 kW | 00:31:48 | 39,0 kWh |
|
76 |
54 kW | 00:32:25 | 39,5 kWh |
|
77 |
53 kW | 00:33:03 | 40,0 kWh |
|
78 |
52 kW | 00:33:41 | 40,6 kWh |
|
79 |
51 kW | 00:34:20 | 41,1 kWh |
|
80 |
50 kW | 00:35:00 | 41,6 kWh |
| 81% | 40 kW | 00:35:45 | 42,1 kWh |
| 82% | 30 kW | 00:36:42 | 42,6 kWh |
| 83% | 29 kW | 00:37:50 | 43,2 kWh |
| 84% | 28 kW | 00:39:01 | 43,7 kWh |
| 85% | 27 kW | 00:40:15 | 44,2 kWh |
| 86% | 26 kW | 00:41:33 | 44,7 kWh |
| 87% | 24 kW | 00:42:53 | 45,2 kWh |
| 88% | 23 kW | 00:44:17 | 45,8 kWh |
| 89% | 22 kW | 00:45:46 | 46,3 kWh |
| 90% | 21 kW | 00:47:19 | 46,8 kWh |
| 91% | 20 kW | 00:48:57 | 47,3 kWh |
| 92% | 19 kW | 00:50:40 | 47,8 kWh |
| 93% | 18 kW | 00:52:30 | 48,4 kWh |
| 94% | 17 kW | 00:54:27 | 48,9 kWh |
| 95% | 16 kW | 00:56:32 | 49,4 kWh |
| 96% | 14 kW | 00:58:46 | 49,9 kWh |
| 97% | 13 kW | 01:01:11 | 50,4 kWh |
| 98% | 12 kW | 01:03:48 | 51,0 kWh |
| 99% | 11 kW | 01:06:41 | 51,5 kWh |
| 100% | 10 kW | 01:09:52 | 52,0 kWh |
Master Your EV Charging Strategy
Understanding charging curves helps you plan efficient road trips and optimize your daily charging routine.
Peak Performance
Charge faster in the 10-80% range for optimal speed
Time Efficiency
Plan stops around optimum charging zones
Temperature Matters
Battery temperature affects charging speed significantly