Most sold EVs in Denmark
November 2025 · Month
Below is the charging curve for Audi A2 e-tron 170 kW, illustrating the charging speed at various battery levels. Additionally, graphs for range and time provide comprehensive details on charging performance.
The charging curve for this model is derived from manufacturer data and insights into the charging performance of similar battery packs.
| SOC Range | Charger output (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 82.4 kW | 57 m 29 s | 79.0 kWh |
| 10-100% | 79.9 kW | 53 m 23 s | 71.1 kWh |
| 10-80% | 109.2 kW | 30 m 22 s | 55.3 kWh |
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 11.2 km (7.0 mi) | 7.6 km (4.7 mi) | 7.2 km (4.5 mi) |
| 10-100% | ? | 10.9 km (6.8 mi) | 7.4 km (4.6 mi) | 7.0 km (4.4 mi) |
| 10-80% | ? | 14.9 km (9.3 mi) | 10.1 km (6.3 mi) | 9.6 km (6.0 mi) |
| SOC | Charger output | Total time from 0% | Energy into battery |
|---|---|---|---|
|
0 |
44 kW | 00:00:00 | 0 kWh |
|
1 |
76 kW | 00:00:49 | 0.8 kWh |
|
2 |
107 kW | 00:01:22 | 1.6 kWh |
|
3 |
140 kW | 00:01:46 | 2.4 kWh |
|
4 |
146 kW | 00:02:07 | 3.2 kWh |
|
5 |
151 kW | 00:02:27 | 4.0 kWh |
|
6 |
152 kW | 00:02:47 | 4.7 kWh |
|
7 |
152 kW | 00:03:07 | 5.5 kWh |
|
8 |
153 kW | 00:03:27 | 6.3 kWh |
|
9 |
153 kW | 00:03:46 | 7.1 kWh |
|
10 |
154 kW | 00:04:06 | 7.9 kWh |
|
11 |
163 kW | 00:04:24 | 8.7 kWh |
|
12 |
164 kW | 00:04:43 | 9.5 kWh |
|
13 |
164 kW | 00:05:01 | 10.3 kWh |
|
14 |
164 kW | 00:05:19 | 11.1 kWh |
|
15 |
164 kW | 00:05:38 | 11.8 kWh |
|
16 |
164 kW | 00:05:56 | 12.6 kWh |
|
17 |
164 kW | 00:06:14 | 13.4 kWh |
|
18 |
164 kW | 00:06:32 | 14.2 kWh |
|
19 |
165 kW | 00:06:51 | 15.0 kWh |
|
20 |
165 kW | 00:07:09 | 15.8 kWh |
|
21 |
166 kW | 00:07:27 | 16.6 kWh |
|
22 |
166 kW | 00:07:45 | 17.4 kWh |
|
23 |
166 kW | 00:08:03 | 18.2 kWh |
|
24 |
167 kW | 00:08:21 | 19.0 kWh |
|
25 |
167 kW | 00:08:39 | 19.8 kWh |
|
26 |
166 kW | 00:08:57 | 20.5 kWh |
|
27 |
166 kW | 00:09:15 | 21.3 kWh |
|
28 |
167 kW | 00:09:33 | 22.1 kWh |
|
29 |
168 kW | 00:09:51 | 22.9 kWh |
|
30 |
167 kW | 00:10:08 | 23.7 kWh |
|
31 |
166 kW | 00:10:26 | 24.5 kWh |
|
32 |
165 kW | 00:10:45 | 25.3 kWh |
|
33 |
164 kW | 00:11:03 | 26.1 kWh |
|
34 |
164 kW | 00:11:21 | 26.9 kWh |
|
35 |
163 kW | 00:11:39 | 27.6 kWh |
|
36 |
163 kW | 00:11:58 | 28.4 kWh |
|
37 |
163 kW | 00:12:16 | 29.2 kWh |
|
38 |
161 kW | 00:12:35 | 30.0 kWh |
|
39 |
159 kW | 00:12:53 | 30.8 kWh |
|
40 |
158 kW | 00:13:12 | 31.6 kWh |
|
41 |
156 kW | 00:13:31 | 32.4 kWh |
|
42 |
152 kW | 00:13:51 | 33.2 kWh |
|
43 |
149 kW | 00:14:11 | 34.0 kWh |
|
44 |
147 kW | 00:14:31 | 34.8 kWh |
|
45 |
145 kW | 00:14:51 | 35.6 kWh |
|
46 |
142 kW | 00:15:12 | 36.3 kWh |
|
47 |
139 kW | 00:15:33 | 37.1 kWh |
|
48 |
137 kW | 00:15:55 | 37.9 kWh |
|
49 |
135 kW | 00:16:17 | 38.7 kWh |
|
50 |
132 kW | 00:16:40 | 39.5 kWh |
|
51 |
130 kW | 00:17:02 | 40.3 kWh |
|
52 |
128 kW | 00:17:26 | 41.1 kWh |
|
53 |
124 kW | 00:17:49 | 41.9 kWh |
|
54 |
111 kW | 00:18:15 | 42.7 kWh |
|
55 |
98 kW | 00:18:43 | 43.4 kWh |
|
56 |
94 kW | 00:19:15 | 44.2 kWh |
|
57 |
92 kW | 00:19:47 | 45.0 kWh |
|
58 |
88 kW | 00:20:20 | 45.8 kWh |
|
59 |
86 kW | 00:20:55 | 46.6 kWh |
|
60 |
84 kW | 00:21:30 | 47.4 kWh |
|
61 |
83 kW | 00:22:06 | 48.2 kWh |
|
62 |
83 kW | 00:22:42 | 49.0 kWh |
|
63 |
87 kW | 00:23:17 | 49.8 kWh |
|
64 |
87 kW | 00:23:51 | 50.6 kWh |
|
65 |
86 kW | 00:24:26 | 51.4 kWh |
|
66 |
83 kW | 00:25:01 | 52.1 kWh |
|
67 |
86 kW | 00:25:37 | 52.9 kWh |
|
68 |
84 kW | 00:26:12 | 53.7 kWh |
|
69 |
82 kW | 00:26:48 | 54.5 kWh |
|
70 |
80 kW | 00:27:25 | 55.3 kWh |
|
71 |
77 kW | 00:28:03 | 56.1 kWh |
|
72 |
77 kW | 00:28:42 | 56.9 kWh |
|
73 |
75 kW | 00:29:21 | 57.7 kWh |
|
74 |
72 kW | 00:30:02 | 58.5 kWh |
|
75 |
71 kW | 00:30:44 | 59.2 kWh |
|
76 |
69 kW | 00:31:27 | 60.0 kWh |
|
77 |
67 kW | 00:32:11 | 60.8 kWh |
|
78 |
66 kW | 00:32:56 | 61.6 kWh |
|
79 |
65 kW | 00:33:42 | 62.4 kWh |
|
80 |
63 kW | 00:34:28 | 63.2 kWh |
|
81 |
62 kW | 00:35:16 | 64.0 kWh |
|
82 |
61 kW | 00:36:05 | 64.8 kWh |
|
83 |
59 kW | 00:36:55 | 65.6 kWh |
|
84 |
57 kW | 00:37:46 | 66.4 kWh |
|
85 |
55 kW | 00:38:40 | 67.2 kWh |
|
86 |
54 kW | 00:39:35 | 67.9 kWh |
|
87 |
53 kW | 00:40:31 | 68.7 kWh |
|
88 |
51 kW | 00:41:28 | 69.5 kWh |
|
89 |
49 kW | 00:42:28 | 70.3 kWh |
|
90 |
48 kW | 00:43:30 | 71.1 kWh |
|
91 |
47 kW | 00:44:33 | 71.9 kWh |
|
92 |
46 kW | 00:45:37 | 72.7 kWh |
|
93 |
44 kW | 00:46:44 | 73.5 kWh |
|
94 |
41 kW | 00:47:54 | 74.3 kWh |
|
95 |
39 kW | 00:49:09 | 75.0 kWh |
|
96 |
36 kW | 00:50:29 | 75.8 kWh |
|
97 |
31 kW | 00:51:58 | 76.6 kWh |
|
98 |
29 kW | 00:53:38 | 77.4 kWh |
|
99 |
26 kW | 00:55:27 | 78.2 kWh |
|
100 |
23 kW | 00:57:29 | 79.0 kWh |
Charger output is the power the charging station delivers. Energy into battery is what actually arrives: around 5% is lost to heat and conversion along the way, and charging times are calculated from that reduced figure. Dividing energy by time therefore gives a value roughly 5% below the charger output column. The 5% is an estimate — real loss varies with temperature, state of charge and the charger used. Read more about charging loss
November 2025 · Month