Courbe de charge et performance de Ford Explorer Standard Range RWD
Dernière modification : nov. 22, 2025Ci-dessous se trouve la courbe de charge pour Ford Explorer Standard Range RWD, illustrant la vitesse de charge à différents niveaux de batterie. De plus, des graphiques pour l'autonomie et le temps fournissent des détails complets sur les performances de charge.
Charging Highlights
Peak DC Speed
135 kW
Battery Capacity
55,0 kWh
Architecture
350 V
55,0 kWh —
Charging Performance
Average 0-100%
54,2 kW
Average 10-100%
51,3 kW
Average 10-80%
69,8 kW
Advanced Metrics
Max C-Rating
2,42C
Avg C-Rating
1,40C
Optimum Zone
0% – 45%
Time Analysis
Range Analysis
Key Insights
Optimum Speed
73,6 kW
Optimum Time
19m 5s
10-80% Time
31 m 16 s
Charging Speed Analysis
| SOC Range | Avg Speed (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 54,2 kW | 57 m 34 s | 52,0 kWh |
| 10-100% | 51,3 kW | 54 m 46 s | 46,8 kWh |
| 10-80% ⭐ | 69,8 kW | 31 m 16 s | 36,4 kWh |
Range Added Per Minute by Driving Cycle
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 6,6 km (4,1 mi) | ? | 4,1 km (2,5 mi) |
| 10-100% | ? | 6,2 km (3,9 mi) | ? | 3,9 km (2,4 mi) |
| 10-80% ⭐ | ? | 8,5 km (5,3 mi) | ? | 5,3 km (3,3 mi) |
Complete Charging Curve Data (0–100% SOC)
| État de charge | Vitesse | Temps | Énergie chargée |
|---|---|---|---|
| 0% | 60 kW | 00:00:00 | 0 kWh |
| 1% | 112 kW | 00:00:23 | 0,5 kWh |
| 2% | 114 kW | 00:00:41 | 1,0 kWh |
| 3% | 123 kW | 00:00:58 | 1,6 kWh |
| 4% | 127 kW | 00:01:14 | 2,1 kWh |
| 5% | 128 kW | 00:01:30 | 2,6 kWh |
| 6% | 129 kW | 00:01:45 | 3,1 kWh |
| 7% | 130 kW | 00:02:01 | 3,6 kWh |
| 8% | 130 kW | 00:02:16 | 4,2 kWh |
| 9% | 130 kW | 00:02:32 | 4,7 kWh |
|
10 |
131 kW | 00:02:47 | 5,2 kWh |
|
11 |
131 kW | 00:03:03 | 5,7 kWh |
|
12 |
131 kW | 00:03:18 | 6,2 kWh |
|
13 |
131 kW | 00:03:33 | 6,8 kWh |
|
14 |
131 kW | 00:03:49 | 7,3 kWh |
|
15 |
131 kW | 00:04:04 | 7,8 kWh |
|
16 |
133 kW | 00:04:19 | 8,3 kWh |
|
17 |
132 kW | 00:04:34 | 8,8 kWh |
|
18 |
133 kW | 00:04:50 | 9,4 kWh |
|
19 |
130 kW | 00:05:05 | 9,9 kWh |
|
20 |
126 kW | 00:05:21 | 10,4 kWh |
|
21 |
122 kW | 00:05:37 | 10,9 kWh |
|
22 |
118 kW | 00:05:54 | 11,4 kWh |
|
23 |
115 kW | 00:06:11 | 12,0 kWh |
|
24 |
111 kW | 00:06:29 | 12,5 kWh |
|
25 |
109 kW | 00:06:47 | 13,0 kWh |
|
26 |
107 kW | 00:07:06 | 13,5 kWh |
|
27 |
106 kW | 00:07:25 | 14,0 kWh |
|
28 |
103 kW | 00:07:44 | 14,6 kWh |
|
29 |
101 kW | 00:08:04 | 15,1 kWh |
|
30 |
100 kW | 00:08:24 | 15,6 kWh |
|
31 |
98 kW | 00:08:44 | 16,1 kWh |
|
32 |
97 kW | 00:09:05 | 16,6 kWh |
|
33 |
96 kW | 00:09:25 | 17,2 kWh |
|
34 |
95 kW | 00:09:47 | 17,7 kWh |
|
35 |
93 kW | 00:10:08 | 18,2 kWh |
|
36 |
91 kW | 00:10:30 | 18,7 kWh |
|
37 |
90 kW | 00:10:52 | 19,2 kWh |
|
38 |
88 kW | 00:11:15 | 19,8 kWh |
|
39 |
87 kW | 00:11:38 | 20,3 kWh |
|
40 |
85 kW | 00:12:01 | 20,8 kWh |
|
41 |
83 kW | 00:12:25 | 21,3 kWh |
|
42 |
82 kW | 00:12:49 | 21,8 kWh |
|
43 |
81 kW | 00:13:14 | 22,4 kWh |
|
44 |
80 kW | 00:13:39 | 22,9 kWh |
|
45 |
79 kW | 00:14:05 | 23,4 kWh |
|
46 |
78 kW | 00:14:30 | 23,9 kWh |
|
47 |
77 kW | 00:14:56 | 24,4 kWh |
|
48 |
75 kW | 00:15:23 | 25,0 kWh |
|
49 |
74 kW | 00:15:50 | 25,5 kWh |
|
50 |
73 kW | 00:16:17 | 26,0 kWh |
|
51 |
72 kW | 00:16:45 | 26,5 kWh |
|
52 |
71 kW | 00:17:13 | 27,0 kWh |
|
53 |
70 kW | 00:17:41 | 27,6 kWh |
|
54 |
69 kW | 00:18:10 | 28,1 kWh |
|
55 |
68 kW | 00:18:40 | 28,6 kWh |
|
56 |
67 kW | 00:19:10 | 29,1 kWh |
|
57 |
66 kW | 00:19:40 | 29,6 kWh |
|
58 |
65 kW | 00:20:11 | 30,2 kWh |
|
59 |
63 kW | 00:20:42 | 30,7 kWh |
|
60 |
62 kW | 00:21:14 | 31,2 kWh |
|
61 |
61 kW | 00:21:47 | 31,7 kWh |
|
62 |
58 kW | 00:22:21 | 32,2 kWh |
|
63 |
57 kW | 00:22:56 | 32,8 kWh |
|
64 |
56 kW | 00:23:32 | 33,3 kWh |
|
65 |
55 kW | 00:24:08 | 33,8 kWh |
|
66 |
54 kW | 00:24:45 | 34,3 kWh |
|
67 |
53 kW | 00:25:22 | 34,8 kWh |
|
68 |
52 kW | 00:26:01 | 35,4 kWh |
|
69 |
50 kW | 00:26:40 | 35,9 kWh |
|
70 |
50 kW | 00:27:20 | 36,4 kWh |
|
71 |
49 kW | 00:28:01 | 36,9 kWh |
|
72 |
50 kW | 00:28:42 | 37,4 kWh |
|
73 |
50 kW | 00:29:22 | 38,0 kWh |
|
74 |
50 kW | 00:30:02 | 38,5 kWh |
|
75 |
50 kW | 00:30:43 | 39,0 kWh |
|
76 |
50 kW | 00:31:23 | 39,5 kWh |
|
77 |
50 kW | 00:32:03 | 40,0 kWh |
|
78 |
50 kW | 00:32:43 | 40,6 kWh |
|
79 |
50 kW | 00:33:24 | 41,1 kWh |
|
80 |
50 kW | 00:34:04 | 41,6 kWh |
| 81% | 50 kW | 00:34:44 | 42,1 kWh |
| 82% | 48 kW | 00:35:25 | 42,6 kWh |
| 83% | 46 kW | 00:36:08 | 43,2 kWh |
| 84% | 44 kW | 00:36:53 | 43,7 kWh |
| 85% | 40 kW | 00:37:41 | 44,2 kWh |
| 86% | 37 kW | 00:38:33 | 44,7 kWh |
| 87% | 33 kW | 00:39:30 | 45,2 kWh |
| 88% | 32 kW | 00:40:32 | 45,8 kWh |
| 89% | 31 kW | 00:41:36 | 46,3 kWh |
| 90% | 30 kW | 00:42:42 | 46,8 kWh |
| 91% | 29 kW | 00:43:50 | 47,3 kWh |
| 92% | 28 kW | 00:45:01 | 47,8 kWh |
| 93% | 26 kW | 00:46:16 | 48,4 kWh |
| 94% | 25 kW | 00:47:35 | 48,9 kWh |
| 95% | 25 kW | 00:48:55 | 49,4 kWh |
| 96% | 24 kW | 00:50:17 | 49,9 kWh |
| 97% | 23 kW | 00:51:43 | 50,4 kWh |
| 98% | 22 kW | 00:53:12 | 51,0 kWh |
| 99% | 21 kW | 00:54:46 | 51,5 kWh |
| 100% | 3 kW | 00:57:34 | 52,0 kWh |
Master Your EV Charging Strategy
Understanding charging curves helps you plan efficient road trips and optimize your daily charging routine.
Peak Performance
Charge faster in the 10-80% range for optimal speed
Time Efficiency
Plan stops around optimum charging zones
Temperature Matters
Battery temperature affects charging speed significantly