MG MG5 Electric Standard Range curva de carregamento e desempenho
Última modificação: nov. 22, 2025Abaixo está a curva de carregamento para MG MG5 Electric Standard Range, ilustrando a velocidade de carregamento em vários níveis de bateria. Além disso, gráficos de autonomia e de tempo fornecem detalhes abrangentes sobre o desempenho de carregamento.
Charging Highlights
Peak DC Speed
87 kW
Battery Capacity
50,3 kWh
50,3 kWh —
Charging Performance
Average 0-100%
44,7 kW
Average 10-100%
45,1 kW
Average 10-80%
71,9 kW
Advanced Metrics
Max C-Rating
1,85C
Avg C-Rating
1,31C
Optimum Zone
7% – 65%
Time Analysis
Range Analysis
Key Insights
Optimum Speed
62,8 kW
Optimum Time
25m 30s
10-80% Time
26 m 51 s
Charging Speed Analysis
| SOC Range | Avg Speed (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 44,7 kW | 1 h 1 m 41 s | 46,0 kWh |
| 10-100% | 45,1 kW | 55 m 3 s | 41,4 kWh |
| 10-80% ⭐ | 71,9 kW | 26 m 51 s | 32,2 kWh |
Range Added Per Minute by Driving Cycle
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 5,2 km (3,2 mi) | ? | 3,2 km (2,0 mi) |
| 10-100% | ? | 5,2 km (3,2 mi) | ? | 3,3 km (2,1 mi) |
| 10-80% ⭐ | ? | 8,3 km (5,2 mi) | ? | 5,2 km (3,2 mi) |
Complete Charging Curve Data (0–100% SOC)
| SoC | Velocidade | Tempo | Energia carregada |
|---|---|---|---|
| 0% | 20 kW | 00:00:00 | 0 kWh |
| 1% | 26 kW | 00:01:16 | 0,5 kWh |
| 2% | 33 kW | 00:02:16 | 0,9 kWh |
| 3% | 39 kW | 00:03:06 | 1,4 kWh |
| 4% | 46 kW | 00:03:48 | 1,8 kWh |
| 5% | 52 kW | 00:04:24 | 2,3 kWh |
| 6% | 58 kW | 00:04:57 | 2,8 kWh |
| 7% | 65 kW | 00:05:26 | 3,2 kWh |
| 8% | 71 kW | 00:05:52 | 3,7 kWh |
| 9% | 78 kW | 00:06:16 | 4,1 kWh |
|
10 |
84 kW | 00:06:38 | 4,6 kWh |
|
11 |
86 kW | 00:06:59 | 5,1 kWh |
|
12 |
88 kW | 00:07:19 | 5,5 kWh |
|
13 |
89 kW | 00:07:39 | 6,0 kWh |
|
14 |
90 kW | 00:07:59 | 6,4 kWh |
|
15 |
90 kW | 00:08:19 | 6,9 kWh |
|
16 |
90 kW | 00:08:39 | 7,4 kWh |
|
17 |
90 kW | 00:08:58 | 7,8 kWh |
|
18 |
90 kW | 00:09:18 | 8,3 kWh |
|
19 |
90 kW | 00:09:38 | 8,7 kWh |
|
20 |
90 kW | 00:09:58 | 9,2 kWh |
|
21 |
90 kW | 00:10:18 | 9,7 kWh |
|
22 |
90 kW | 00:10:37 | 10,1 kWh |
|
23 |
89 kW | 00:10:57 | 10,6 kWh |
|
24 |
89 kW | 00:11:17 | 11,0 kWh |
|
25 |
89 kW | 00:11:37 | 11,5 kWh |
|
26 |
89 kW | 00:11:57 | 12,0 kWh |
|
27 |
90 kW | 00:12:17 | 12,4 kWh |
|
28 |
90 kW | 00:12:37 | 12,9 kWh |
|
29 |
91 kW | 00:12:57 | 13,3 kWh |
|
30 |
92 kW | 00:13:16 | 13,8 kWh |
|
31 |
92 kW | 00:13:35 | 14,3 kWh |
|
32 |
92 kW | 00:13:55 | 14,7 kWh |
|
33 |
92 kW | 00:14:14 | 15,2 kWh |
|
34 |
92 kW | 00:14:34 | 15,6 kWh |
|
35 |
93 kW | 00:14:53 | 16,1 kWh |
|
36 |
93 kW | 00:15:12 | 16,6 kWh |
|
37 |
93 kW | 00:15:31 | 17,0 kWh |
|
38 |
93 kW | 00:15:50 | 17,5 kWh |
|
39 |
93 kW | 00:16:09 | 17,9 kWh |
|
40 |
93 kW | 00:16:29 | 18,4 kWh |
|
41 |
93 kW | 00:16:48 | 18,9 kWh |
|
42 |
92 kW | 00:17:07 | 19,3 kWh |
|
43 |
91 kW | 00:17:26 | 19,8 kWh |
|
44 |
89 kW | 00:17:46 | 20,2 kWh |
|
45 |
88 kW | 00:18:06 | 20,7 kWh |
|
46 |
87 kW | 00:18:27 | 21,2 kWh |
|
47 |
86 kW | 00:18:47 | 21,6 kWh |
|
48 |
85 kW | 00:19:08 | 22,1 kWh |
|
49 |
83 kW | 00:19:29 | 22,5 kWh |
|
50 |
82 kW | 00:19:51 | 23,0 kWh |
|
51 |
81 kW | 00:20:13 | 23,5 kWh |
|
52 |
80 kW | 00:20:35 | 23,9 kWh |
|
53 |
79 kW | 00:20:57 | 24,4 kWh |
|
54 |
78 kW | 00:21:20 | 24,8 kWh |
|
55 |
77 kW | 00:21:43 | 25,3 kWh |
|
56 |
76 kW | 00:22:06 | 25,8 kWh |
|
57 |
74 kW | 00:22:30 | 26,2 kWh |
|
58 |
70 kW | 00:22:55 | 26,7 kWh |
|
59 |
69 kW | 00:23:20 | 27,1 kWh |
|
60 |
69 kW | 00:23:46 | 27,6 kWh |
|
61 |
69 kW | 00:24:12 | 28,1 kWh |
|
62 |
69 kW | 00:24:38 | 28,5 kWh |
|
63 |
69 kW | 00:25:03 | 29,0 kWh |
|
64 |
68 kW | 00:25:29 | 29,4 kWh |
|
65 |
67 kW | 00:25:56 | 29,9 kWh |
|
66 |
66 kW | 00:26:23 | 30,4 kWh |
|
67 |
65 kW | 00:26:50 | 30,8 kWh |
|
68 |
63 kW | 00:27:18 | 31,3 kWh |
|
69 |
62 kW | 00:27:46 | 31,7 kWh |
|
70 |
61 kW | 00:28:15 | 32,2 kWh |
|
71 |
60 kW | 00:28:44 | 32,7 kWh |
|
72 |
59 kW | 00:29:14 | 33,1 kWh |
|
73 |
58 kW | 00:29:45 | 33,6 kWh |
|
74 |
58 kW | 00:30:16 | 34,0 kWh |
|
75 |
57 kW | 00:30:47 | 34,5 kWh |
|
76 |
56 kW | 00:31:18 | 35,0 kWh |
|
77 |
55 kW | 00:31:50 | 35,4 kWh |
|
78 |
55 kW | 00:32:22 | 35,9 kWh |
|
79 |
54 kW | 00:32:55 | 36,3 kWh |
|
80 |
51 kW | 00:33:29 | 36,8 kWh |
| 81% | 51 kW | 00:34:04 | 37,3 kWh |
| 82% | 51 kW | 00:34:39 | 37,7 kWh |
| 83% | 42 kW | 00:35:17 | 38,2 kWh |
| 84% | 36 kW | 00:36:03 | 38,6 kWh |
| 85% | 36 kW | 00:36:52 | 39,1 kWh |
| 86% | 36 kW | 00:37:42 | 39,6 kWh |
| 87% | 36 kW | 00:38:31 | 40,0 kWh |
| 88% | 32 kW | 00:39:24 | 40,5 kWh |
| 89% | 26 kW | 00:40:25 | 40,9 kWh |
| 90% | 21 kW | 00:41:41 | 41,4 kWh |
| 91% | 20 kW | 00:43:08 | 41,9 kWh |
| 92% | 19 kW | 00:44:40 | 42,3 kWh |
| 93% | 18 kW | 00:46:17 | 42,8 kWh |
| 94% | 17 kW | 00:48:01 | 43,2 kWh |
| 95% | 16 kW | 00:49:52 | 43,7 kWh |
| 96% | 14 kW | 00:51:51 | 44,2 kWh |
| 97% | 13 kW | 00:54:00 | 44,6 kWh |
| 98% | 12 kW | 00:56:20 | 45,1 kWh |
| 99% | 11 kW | 00:58:52 | 45,5 kWh |
| 100% | 10 kW | 01:01:41 | 46,0 kWh |
Master Your EV Charging Strategy
Understanding charging curves helps you plan efficient road trips and optimize your daily charging routine.
Peak Performance
Charge faster in the 10-80% range for optimal speed
Time Efficiency
Plan stops around optimum charging zones
Temperature Matters
Battery temperature affects charging speed significantly