SKODA ENYAQ COUPÉ RS ladekurve og ytelse
Sist endret: nov. 22, 2025Under er ladekurven for SKODA ENYAQ COUPÉ RS, som viser ladehastigheten ved ulike batterinivåer. I tillegg gir grafer for rekkevidde og tid omfattende detaljer om ladeytelsen.
Charging Highlights
Peak DC Speed
185 kW
Battery Capacity
84,0 kWh
Architecture
350 V
84,0 kWh — 84kWh
Charging Performance
Average 0-100%
75,9 kW
Average 10-100%
73,7 kW
Average 10-80%
118,1 kW
Advanced Metrics
Max C-Rating
2,11C
Avg C-Rating
1,38C
Optimum Zone
4% – 53%
Time Analysis
Range Analysis
Key Insights
Optimum Speed
113,6 kW
Optimum Time
20m 26s
10-80% Time
28 m 5 s
Charging Speed Analysis
| SOC Range | Avg Speed (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 75,9 kW | 1 h 2 m 27 s | 79,0 kWh |
| 10-100% | 73,7 kW | 57 m 53 s | 71,1 kWh |
| 10-80% ⭐ | 118,1 kW | 28 m 5 s | 55,3 kWh |
Range Added Per Minute by Driving Cycle
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 8,8 km (5,5 mi) | 6,3 km (3,9 mi) | 6,0 km (3,7 mi) |
| 10-100% | ? | 8,5 km (5,3 mi) | 6,1 km (3,8 mi) | 5,8 km (3,6 mi) |
| 10-80% ⭐ | ? | 13,6 km (8,5 mi) | 9,8 km (6,1 mi) | 9,4 km (5,8 mi) |
Complete Charging Curve Data (0–100% SOC)
| Ladenivå | Hastighet | Tid | Energi ladet |
|---|---|---|---|
| 0% | 50 kW | 00:00:00 | 0 kWh |
| 1% | 70 kW | 00:00:51 | 0,8 kWh |
| 2% | 89 kW | 00:01:29 | 1,6 kWh |
| 3% | 105 kW | 00:02:01 | 2,4 kWh |
| 4% | 119 kW | 00:02:28 | 3,2 kWh |
| 5% | 137 kW | 00:02:52 | 4,0 kWh |
| 6% | 145 kW | 00:03:14 | 4,7 kWh |
| 7% | 150 kW | 00:03:34 | 5,5 kWh |
| 8% | 154 kW | 00:03:55 | 6,3 kWh |
| 9% | 158 kW | 00:04:14 | 7,1 kWh |
|
10 |
163 kW | 00:04:33 | 7,9 kWh |
|
11 |
161 kW | 00:04:52 | 8,7 kWh |
|
12 |
162 kW | 00:05:11 | 9,5 kWh |
|
13 |
165 kW | 00:05:30 | 10,3 kWh |
|
14 |
166 kW | 00:05:48 | 11,1 kWh |
|
15 |
168 kW | 00:06:06 | 11,8 kWh |
|
16 |
170 kW | 00:06:25 | 12,6 kWh |
|
17 |
171 kW | 00:06:43 | 13,4 kWh |
|
18 |
173 kW | 00:07:00 | 14,2 kWh |
|
19 |
175 kW | 00:07:18 | 15,0 kWh |
|
20 |
175 kW | 00:07:35 | 15,8 kWh |
|
21 |
175 kW | 00:07:53 | 16,6 kWh |
|
22 |
175 kW | 00:08:10 | 17,4 kWh |
|
23 |
175 kW | 00:08:28 | 18,2 kWh |
|
24 |
175 kW | 00:08:45 | 19,0 kWh |
|
25 |
175 kW | 00:09:03 | 19,8 kWh |
|
26 |
176 kW | 00:09:20 | 20,5 kWh |
|
27 |
176 kW | 00:09:38 | 21,3 kWh |
|
28 |
176 kW | 00:09:55 | 22,1 kWh |
|
29 |
176 kW | 00:10:12 | 22,9 kWh |
|
30 |
176 kW | 00:10:30 | 23,7 kWh |
|
31 |
177 kW | 00:10:47 | 24,5 kWh |
|
32 |
176 kW | 00:11:04 | 25,3 kWh |
|
33 |
176 kW | 00:11:22 | 26,1 kWh |
|
34 |
176 kW | 00:11:39 | 26,9 kWh |
|
35 |
175 kW | 00:11:56 | 27,6 kWh |
|
36 |
175 kW | 00:12:14 | 28,4 kWh |
|
37 |
174 kW | 00:12:31 | 29,2 kWh |
|
38 |
171 kW | 00:12:49 | 30,0 kWh |
|
39 |
169 kW | 00:13:07 | 30,8 kWh |
|
40 |
164 kW | 00:13:26 | 31,6 kWh |
|
41 |
162 kW | 00:13:44 | 32,4 kWh |
|
42 |
160 kW | 00:14:03 | 33,2 kWh |
|
43 |
157 kW | 00:14:23 | 34,0 kWh |
|
44 |
155 kW | 00:14:42 | 34,8 kWh |
|
45 |
150 kW | 00:15:02 | 35,6 kWh |
|
46 |
148 kW | 00:15:23 | 36,3 kWh |
|
47 |
148 kW | 00:15:43 | 37,1 kWh |
|
48 |
146 kW | 00:16:04 | 37,9 kWh |
|
49 |
144 kW | 00:16:25 | 38,7 kWh |
|
50 |
142 kW | 00:16:47 | 39,5 kWh |
|
51 |
139 kW | 00:17:08 | 40,3 kWh |
|
52 |
135 kW | 00:17:31 | 41,1 kWh |
|
53 |
123 kW | 00:17:55 | 41,9 kWh |
|
54 |
120 kW | 00:18:20 | 42,7 kWh |
|
55 |
116 kW | 00:18:46 | 43,4 kWh |
|
56 |
114 kW | 00:19:12 | 44,2 kWh |
|
57 |
110 kW | 00:19:40 | 45,0 kWh |
|
58 |
107 kW | 00:20:08 | 45,8 kWh |
|
59 |
106 kW | 00:20:36 | 46,6 kWh |
|
60 |
104 kW | 00:21:06 | 47,4 kWh |
|
61 |
102 kW | 00:21:35 | 48,2 kWh |
|
62 |
102 kW | 00:22:05 | 49,0 kWh |
|
63 |
100 kW | 00:22:35 | 49,8 kWh |
|
64 |
98 kW | 00:23:06 | 50,6 kWh |
|
65 |
98 kW | 00:23:38 | 51,4 kWh |
|
66 |
95 kW | 00:24:09 | 52,1 kWh |
|
67 |
97 kW | 00:24:41 | 52,9 kWh |
|
68 |
95 kW | 00:25:13 | 53,7 kWh |
|
69 |
95 kW | 00:25:45 | 54,5 kWh |
|
70 |
93 kW | 00:26:18 | 55,3 kWh |
|
71 |
90 kW | 00:26:51 | 56,1 kWh |
|
72 |
88 kW | 00:27:25 | 56,9 kWh |
|
73 |
85 kW | 00:28:01 | 57,7 kWh |
|
74 |
83 kW | 00:28:37 | 58,5 kWh |
|
75 |
80 kW | 00:29:15 | 59,2 kWh |
|
76 |
78 kW | 00:29:53 | 60,0 kWh |
|
77 |
76 kW | 00:30:33 | 60,8 kWh |
|
78 |
74 kW | 00:31:14 | 61,6 kWh |
|
79 |
73 kW | 00:31:56 | 62,4 kWh |
|
80 |
70 kW | 00:32:38 | 63,2 kWh |
| 81% | 67 kW | 00:33:23 | 64,0 kWh |
| 82% | 61 kW | 00:34:11 | 64,8 kWh |
| 83% | 55 kW | 00:35:03 | 65,6 kWh |
| 84% | 49 kW | 00:36:02 | 66,4 kWh |
| 85% | 43 kW | 00:37:09 | 67,2 kWh |
| 86% | 36 kW | 00:38:26 | 67,9 kWh |
| 87% | 32 kW | 00:39:56 | 68,7 kWh |
| 88% | 32 kW | 00:41:32 | 69,5 kWh |
| 89% | 32 kW | 00:43:07 | 70,3 kWh |
| 90% | 32 kW | 00:44:43 | 71,1 kWh |
| 91% | 32 kW | 00:46:18 | 71,9 kWh |
| 92% | 32 kW | 00:47:54 | 72,7 kWh |
| 93% | 32 kW | 00:49:30 | 73,5 kWh |
| 94% | 30 kW | 00:51:08 | 74,3 kWh |
| 95% | 30 kW | 00:52:50 | 75,0 kWh |
| 96% | 28 kW | 00:54:36 | 75,8 kWh |
| 97% | 27 kW | 00:56:27 | 76,6 kWh |
| 98% | 26 kW | 00:58:22 | 77,4 kWh |
| 99% | 25 kW | 01:00:22 | 78,2 kWh |
| 100% | 24 kW | 01:02:27 | 79,0 kWh |
Master Your EV Charging Strategy
Understanding charging curves helps you plan efficient road trips and optimize your daily charging routine.
Peak Performance
Charge faster in the 10-80% range for optimal speed
Time Efficiency
Plan stops around optimum charging zones
Temperature Matters
Battery temperature affects charging speed significantly