Last modified:: Jun 29, 2025

Tesla Model Y Long Range charging curve & performance

Below is the charging curve for Tesla Model Y Long Range, illustrating the charging speed at various battery levels. Additionally, graphs for range and time provide comprehensive details on charging performance.

82.0 kWh —

Spec Value
Average charging speed 0 - 100% 66.3 kW
Average charging speed 10-100% 62.8 kW
Average charging speed 10-90% 78.8 kW
Average charging speed 10-80% 96.3 kW
Max C-Rate 2.99
Average C-Rate 1.33
Optimum charging area 5% – 44%
Optimum charging speed included 5 minutes loss 110.2 kW
Optimum charge stop time 16m 46s
Spec Value
Charging time 0 - 100% 1 h 11 m 28 s
Charging time 10-100% 1 h 7 m 54 s
Charging time 10-80% 34 m 27 s
EPA cycle WLTP cycle 70 mph 120 km/h
Range per minute 0-100% 7.2 km (4.5 mi) 7.9 km (4.9 mi) 6.7 km (4.2 mi) 5.7 km (3.5 mi)
Range per minute 10-100% 6.8 km (4.2 mi) 7.5 km (4.7 mi) 6.3 km (3.9 mi) 5.4 km (3.4 mi)
Range per minute 10-80% 10.5 km (6.5 mi) 11.5 km (7.1 mi) 9.7 km (6.0 mi) 8.2 km (5.1 mi)
SOC Speed Time Energy charged
0 % 100 kW 00:00:00 0 kWh
1 % 103 kW 00:00:30 0.8 kWh
2 % 108 kW 00:00:59 1.6 kWh
3 % 108 kW 00:01:27 2.4 kWh
4 % 108 kW 00:01:55 3.2 kWh
5 % 108 kW 00:02:24 4.0 kWh
6 % 230 kW 00:02:42 4.7 kWh
7 % 235 kW 00:02:55 5.5 kWh
8 % 240 kW 00:03:08 6.3 kWh
9 % 245 kW 00:03:20 7.1 kWh
10 % 225 kW 00:03:33 7.9 kWh
11 % 222 kW 00:03:47 8.7 kWh
12 % 216 kW 00:04:01 9.5 kWh
13 % 211 kW 00:04:15 10.3 kWh
14 % 207 kW 00:04:30 11.1 kWh
15 % 203 kW 00:04:45 11.8 kWh
16 % 202 kW 00:05:00 12.6 kWh
17 % 195 kW 00:05:15 13.4 kWh
18 % 193 kW 00:05:31 14.2 kWh
19 % 193 kW 00:05:47 15.0 kWh
20 % 189 kW 00:06:03 15.8 kWh
21 % 185 kW 00:06:19 16.6 kWh
22 % 183 kW 00:06:36 17.4 kWh
23 % 180 kW 00:06:53 18.2 kWh
24 % 178 kW 00:07:10 19.0 kWh
25 % 173 kW 00:07:27 19.8 kWh
26 % 171 kW 00:07:45 20.5 kWh
27 % 168 kW 00:08:03 21.3 kWh
28 % 165 kW 00:08:21 22.1 kWh
29 % 161 kW 00:08:40 22.9 kWh
30 % 159 kW 00:08:59 23.7 kWh
31 % 153 kW 00:09:19 24.5 kWh
32 % 152 kW 00:09:39 25.3 kWh
33 % 149 kW 00:09:59 26.1 kWh
34 % 147 kW 00:10:20 26.9 kWh
35 % 145 kW 00:10:41 27.6 kWh
36 % 142 kW 00:11:02 28.4 kWh
37 % 139 kW 00:11:24 29.2 kWh
38 % 136 kW 00:11:46 30.0 kWh
39 % 133 kW 00:12:09 30.8 kWh
40 % 130 kW 00:12:32 31.6 kWh
41 % 127 kW 00:12:56 32.4 kWh
42 % 125 kW 00:13:20 33.2 kWh
43 % 122 kW 00:13:45 34.0 kWh
44 % 119 kW 00:14:10 34.8 kWh
45 % 116 kW 00:14:36 35.6 kWh
46 % 113 kW 00:15:03 36.3 kWh
47 % 110 kW 00:15:31 37.1 kWh
48 % 108 kW 00:15:59 37.9 kWh
49 % 106 kW 00:16:27 38.7 kWh
50 % 103 kW 00:16:57 39.5 kWh
51 % 101 kW 00:17:26 40.3 kWh
52 % 98 kW 00:17:57 41.1 kWh
53 % 96 kW 00:18:29 41.9 kWh
54 % 94 kW 00:19:01 42.7 kWh
55 % 92 kW 00:19:34 43.4 kWh
56 % 89 kW 00:20:08 44.2 kWh
57 % 87 kW 00:20:42 45.0 kWh
58 % 85 kW 00:21:18 45.8 kWh
59 % 83 kW 00:21:54 46.6 kWh
60 % 82 kW 00:22:31 47.4 kWh
61 % 81 kW 00:23:09 48.2 kWh
62 % 79 kW 00:23:47 49.0 kWh
63 % 78 kW 00:24:26 49.8 kWh
64 % 77 kW 00:25:06 50.6 kWh
65 % 76 kW 00:25:46 51.4 kWh
66 % 75 kW 00:26:26 52.1 kWh
67 % 74 kW 00:27:07 52.9 kWh
68 % 73 kW 00:27:49 53.7 kWh
69 % 72 kW 00:28:31 54.5 kWh
70 % 71 kW 00:29:14 55.3 kWh
71 % 69 kW 00:29:57 56.1 kWh
72 % 68 kW 00:30:42 56.9 kWh
73 % 67 kW 00:31:27 57.7 kWh
74 % 65 kW 00:32:14 58.5 kWh
75 % 61 kW 00:33:02 59.2 kWh
76 % 56 kW 00:33:54 60.0 kWh
77 % 53 kW 00:34:51 60.8 kWh
78 % 49 kW 00:35:50 61.6 kWh
79 % 47 kW 00:36:54 62.4 kWh
80 % 45 kW 00:38:01 63.2 kWh
81 % 42 kW 00:39:11 64.0 kWh
82 % 41 kW 00:40:25 64.8 kWh
83 % 40 kW 00:41:40 65.6 kWh
84 % 39 kW 00:42:58 66.4 kWh
85 % 37 kW 00:44:18 67.2 kWh
86 % 36 kW 00:45:42 67.9 kWh
87 % 35 kW 00:47:08 68.7 kWh
88 % 34 kW 00:48:37 69.5 kWh
89 % 33 kW 00:50:08 70.3 kWh
90 % 32 kW 00:51:42 71.1 kWh
91 % 32 kW 00:53:18 71.9 kWh
92 % 32 kW 00:54:53 72.7 kWh
93 % 32 kW 00:56:29 73.5 kWh
94 % 32 kW 00:58:04 74.3 kWh
95 % 30 kW 00:59:43 75.0 kWh
96 % 27 kW 01:01:30 75.8 kWh
97 % 25 kW 01:03:28 76.6 kWh
98 % 22 kW 01:05:38 77.4 kWh
99 % 18 kW 01:08:11 78.2 kWh
100 % 13 kW 01:11:28 79.0 kWh