MG MG4 Premium Long Range charging curve & performance
Below is the charging curve for MG MG4 Premium Long Range, illustrating the charging speed at various battery levels. Additionally, graphs for range and time provide comprehensive details on charging performance.
Charging Highlights
64.0 kWh — MG LFP 64 kWh
The charging curve for this model is derived from manufacturer data and insights into the charging performance of similar battery packs.
Charging Performance
Advanced Metrics
Time Analysis
Range Analysis
Key Insights
Charging Speed Analysis
| SOC Range | Charger output (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 61.3 kW | 1 h 0 m 26 s | 61.7 kWh |
| 10-100% | 59.2 kW | 56 m 19 s | 55.5 kWh |
| 10-80% | 103.5 kW | 25 m 1 s | 43.2 kWh |
Range Added Per Minute by Driving Cycle
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | ? | 7.5 km (4.7 mi) | ? | 4.9 km (3.0 mi) |
| 10-100% | ? | 7.2 km (4.5 mi) | ? | 4.7 km (2.9 mi) |
| 10-80% | ? | 12.6 km (7.8 mi) | ? | 8.2 km (5.1 mi) |
Charging Curve Data (0–100% SOC)
| SOC | Charger output | Total time from 0% | Energy into battery |
|---|---|---|---|
|
0 |
40 kW | 00:00:00 | 0 kWh |
|
1 |
56 kW | 00:00:48 | 0.6 kWh |
|
2 |
72 kW | 00:01:25 | 1.2 kWh |
|
3 |
88 kW | 00:01:54 | 1.9 kWh |
|
4 |
104 kW | 00:02:18 | 2.5 kWh |
|
5 |
120 kW | 00:02:39 | 3.1 kWh |
|
6 |
126 kW | 00:02:58 | 3.7 kWh |
|
7 |
132 kW | 00:03:16 | 4.3 kWh |
|
8 |
138 kW | 00:03:34 | 4.9 kWh |
|
9 |
144 kW | 00:03:50 | 5.6 kWh |
|
10 |
150 kW | 00:04:06 | 6.2 kWh |
|
11 |
151 kW | 00:04:22 | 6.8 kWh |
|
12 |
152 kW | 00:04:37 | 7.4 kWh |
|
13 |
152 kW | 00:04:53 | 8.0 kWh |
|
14 |
153 kW | 00:05:08 | 8.6 kWh |
|
15 |
154 kW | 00:05:23 | 9.3 kWh |
|
16 |
154 kW | 00:05:38 | 9.9 kWh |
|
17 |
154 kW | 00:05:53 | 10.5 kWh |
|
18 |
154 kW | 00:06:09 | 11.1 kWh |
|
19 |
154 kW | 00:06:24 | 11.7 kWh |
|
20 |
154 kW | 00:06:39 | 12.3 kWh |
|
21 |
153 kW | 00:06:54 | 13.0 kWh |
|
22 |
152 kW | 00:07:09 | 13.6 kWh |
|
23 |
152 kW | 00:07:25 | 14.2 kWh |
|
24 |
151 kW | 00:07:40 | 14.8 kWh |
|
25 |
150 kW | 00:07:56 | 15.4 kWh |
|
26 |
149 kW | 00:08:12 | 16.0 kWh |
|
27 |
148 kW | 00:08:27 | 16.7 kWh |
|
28 |
147 kW | 00:08:43 | 17.3 kWh |
|
29 |
146 kW | 00:08:59 | 17.9 kWh |
|
30 |
145 kW | 00:09:15 | 18.5 kWh |
|
31 |
143 kW | 00:09:31 | 19.1 kWh |
|
32 |
141 kW | 00:09:48 | 19.7 kWh |
|
33 |
139 kW | 00:10:05 | 20.4 kWh |
|
34 |
137 kW | 00:10:21 | 21.0 kWh |
|
35 |
135 kW | 00:10:39 | 21.6 kWh |
|
36 |
133 kW | 00:10:56 | 22.2 kWh |
|
37 |
131 kW | 00:11:14 | 22.8 kWh |
|
38 |
129 kW | 00:11:32 | 23.4 kWh |
|
39 |
127 kW | 00:11:50 | 24.1 kWh |
|
40 |
125 kW | 00:12:09 | 24.7 kWh |
|
41 |
124 kW | 00:12:27 | 25.3 kWh |
|
42 |
122 kW | 00:12:46 | 25.9 kWh |
|
43 |
121 kW | 00:13:06 | 26.5 kWh |
|
44 |
119 kW | 00:13:25 | 27.1 kWh |
|
45 |
118 kW | 00:13:45 | 27.8 kWh |
|
46 |
117 kW | 00:14:05 | 28.4 kWh |
|
47 |
116 kW | 00:14:25 | 29.0 kWh |
|
48 |
114 kW | 00:14:45 | 29.6 kWh |
|
49 |
113 kW | 00:15:06 | 30.2 kWh |
|
50 |
112 kW | 00:15:27 | 30.8 kWh |
|
51 |
111 kW | 00:15:48 | 31.5 kWh |
|
52 |
109 kW | 00:16:09 | 32.1 kWh |
|
53 |
108 kW | 00:16:30 | 32.7 kWh |
|
54 |
106 kW | 00:16:52 | 33.3 kWh |
|
55 |
105 kW | 00:17:14 | 33.9 kWh |
|
56 |
104 kW | 00:17:37 | 34.6 kWh |
|
57 |
102 kW | 00:18:00 | 35.2 kWh |
|
58 |
101 kW | 00:18:23 | 35.8 kWh |
|
59 |
99 kW | 00:18:46 | 36.4 kWh |
|
60 |
98 kW | 00:19:10 | 37.0 kWh |
|
61 |
96 kW | 00:19:34 | 37.6 kWh |
|
62 |
95 kW | 00:19:58 | 38.3 kWh |
|
63 |
93 kW | 00:20:23 | 38.9 kWh |
|
64 |
92 kW | 00:20:48 | 39.5 kWh |
|
65 |
90 kW | 00:21:14 | 40.1 kWh |
|
66 |
88 kW | 00:21:40 | 40.7 kWh |
|
67 |
86 kW | 00:22:07 | 41.3 kWh |
|
68 |
84 kW | 00:22:35 | 42.0 kWh |
|
69 |
82 kW | 00:23:03 | 42.6 kWh |
|
70 |
80 kW | 00:23:32 | 43.2 kWh |
|
71 |
78 kW | 00:24:01 | 43.8 kWh |
|
72 |
76 kW | 00:24:32 | 44.4 kWh |
|
73 |
74 kW | 00:25:03 | 45.0 kWh |
|
74 |
72 kW | 00:25:35 | 45.7 kWh |
|
75 |
70 kW | 00:26:08 | 46.3 kWh |
|
76 |
68 kW | 00:26:42 | 46.9 kWh |
|
77 |
66 kW | 00:27:17 | 47.5 kWh |
|
78 |
64 kW | 00:27:53 | 48.1 kWh |
|
79 |
62 kW | 00:28:30 | 48.7 kWh |
|
80 |
60 kW | 00:29:08 | 49.4 kWh |
|
81 |
57 kW | 00:29:48 | 50.0 kWh |
|
82 |
54 kW | 00:30:30 | 50.6 kWh |
|
83 |
51 kW | 00:31:15 | 51.2 kWh |
|
84 |
48 kW | 00:32:02 | 51.8 kWh |
|
85 |
45 kW | 00:32:52 | 52.4 kWh |
|
86 |
42 kW | 00:33:46 | 53.1 kWh |
|
87 |
40 kW | 00:34:43 | 53.7 kWh |
|
88 |
37 kW | 00:35:43 | 54.3 kWh |
|
89 |
35 kW | 00:36:48 | 54.9 kWh |
|
90 |
32 kW | 00:37:59 | 55.5 kWh |
|
91 |
30 kW | 00:39:15 | 56.1 kWh |
|
92 |
27 kW | 00:40:37 | 56.8 kWh |
|
93 |
25 kW | 00:42:07 | 57.4 kWh |
|
94 |
22 kW | 00:43:46 | 58.0 kWh |
|
95 |
20 kW | 00:45:36 | 58.6 kWh |
|
96 |
18 kW | 00:47:41 | 59.2 kWh |
|
97 |
15 kW | 00:50:03 | 59.8 kWh |
|
98 |
13 kW | 00:52:50 | 60.5 kWh |
|
99 |
10 kW | 00:56:12 | 61.1 kWh |
|
100 |
8 kW | 01:00:26 | 61.7 kWh |
Charger output is the power the charging station delivers. Energy into battery is what actually arrives: around 5% is lost to heat and conversion along the way, and charging times are calculated from that reduced figure. Dividing energy by time therefore gives a value roughly 5% below the charger output column. The 5% is an estimate — real loss varies with temperature, state of charge and the charger used. Read more about charging loss
More information
Alternative Models
In the rapidly expanding EV market, EVKX.net has identified several alternatives to the MG MG4 Premium Long Range that are worth considering based on features, specifications, and pricing.
Compare These Vehicles
Most sold EVs in USA
Q3 2025 · Quarter