Last modified:: May 28, 2025

Citroën ë-C3 charging curve & performance

Below is the charging curve for Citroën ë-C3, illustrating the charging speed at various battery levels. Additionally, graphs for range and time provide comprehensive details on charging performance.

45.0 kWh —

The charging curve for this model is derived from manufacturer data and insights into the charging performance of similar battery packs.
Spec Value
Average charging speed 0 - 100% 26.4 kW
Average charging speed 10-100% 29.7 kW
Average charging speed 10-90% 59.4 kW
Average charging speed 10-80% 71.7 kW
Max C-Rate 2.22
Average C-Rate 1.39
Optimum charging area 14% – 68%
Optimum charging speed included 5 minutes loss 63.2 kW
Optimum charge stop time 22m 33s
Spec Value
Charging time 0 - 100% 1 h 40 m 10 s
Charging time 10-100% 1 h 19 m 52 s
Charging time 10-80% 25 m 46 s
EPA cycle WLTP cycle 70 mph 120 km/h
Range per minute 0-100% ? 3.3 km (2.1 mi) 1.9 km (1.2 mi) 1.8 km (1.1 mi)
Range per minute 10-100% ? 3.7 km (2.3 mi) 2.2 km (1.4 mi) 2.1 km (1.3 mi)
Range per minute 10-80% ? 8.9 km (5.5 mi) 5.2 km (3.2 mi) 5.0 km (3.1 mi)
SOC Speed Time Energy charged
0 % 1 kW 00:00:00 0 kWh
1 % 6 kW 00:08:10 0.4 kWh
2 % 11 kW 00:11:32 0.9 kWh
3 % 16 kW 00:13:39 1.3 kWh
4 % 21 kW 00:15:12 1.8 kWh
5 % 26 kW 00:16:25 2.2 kWh
6 % 31 kW 00:17:26 2.6 kWh
7 % 36 kW 00:18:17 3.1 kWh
8 % 41 kW 00:19:02 3.5 kWh
9 % 46 kW 00:19:41 4.0 kWh
10 % 50 kW 00:20:17 4.4 kWh
11 % 55 kW 00:20:49 4.8 kWh
12 % 60 kW 00:21:18 5.3 kWh
13 % 65 kW 00:21:45 5.7 kWh
14 % 70 kW 00:22:10 6.2 kWh
15 % 75 kW 00:22:34 6.6 kWh
16 % 80 kW 00:22:56 7.0 kWh
17 % 85 kW 00:23:16 7.5 kWh
18 % 90 kW 00:23:36 7.9 kWh
19 % 95 kW 00:23:54 8.4 kWh
20 % 100 kW 00:24:12 8.8 kWh
21 % 100 kW 00:24:29 9.2 kWh
22 % 99 kW 00:24:46 9.7 kWh
23 % 99 kW 00:25:03 10.1 kWh
24 % 98 kW 00:25:20 10.6 kWh
25 % 98 kW 00:25:38 11.0 kWh
26 % 97 kW 00:25:55 11.4 kWh
27 % 97 kW 00:26:13 11.9 kWh
28 % 96 kW 00:26:30 12.3 kWh
29 % 96 kW 00:26:48 12.8 kWh
30 % 95 kW 00:27:06 13.2 kWh
31 % 95 kW 00:27:24 13.6 kWh
32 % 94 kW 00:27:42 14.1 kWh
33 % 94 kW 00:28:00 14.5 kWh
34 % 93 kW 00:28:18 15.0 kWh
35 % 93 kW 00:28:36 15.4 kWh
36 % 93 kW 00:28:55 15.8 kWh
37 % 92 kW 00:29:13 16.3 kWh
38 % 92 kW 00:29:32 16.7 kWh
39 % 91 kW 00:29:50 17.2 kWh
40 % 91 kW 00:30:09 17.6 kWh
41 % 90 kW 00:30:28 18.0 kWh
42 % 90 kW 00:30:47 18.5 kWh
43 % 89 kW 00:31:06 18.9 kWh
44 % 89 kW 00:31:25 19.4 kWh
45 % 88 kW 00:31:44 19.8 kWh
46 % 88 kW 00:32:04 20.2 kWh
47 % 87 kW 00:32:23 20.7 kWh
48 % 87 kW 00:32:43 21.1 kWh
49 % 87 kW 00:33:02 21.6 kWh
50 % 86 kW 00:33:22 22.0 kWh
51 % 86 kW 00:33:42 22.4 kWh
52 % 85 kW 00:34:02 22.9 kWh
53 % 85 kW 00:34:22 23.3 kWh
54 % 84 kW 00:34:42 23.8 kWh
55 % 84 kW 00:35:02 24.2 kWh
56 % 83 kW 00:35:23 24.6 kWh
57 % 83 kW 00:35:43 25.1 kWh
58 % 82 kW 00:36:04 25.5 kWh
59 % 82 kW 00:36:25 26.0 kWh
60 % 81 kW 00:36:45 26.4 kWh
61 % 81 kW 00:37:06 26.8 kWh
62 % 80 kW 00:37:28 27.3 kWh
63 % 80 kW 00:37:49 27.7 kWh
64 % 78 kW 00:38:10 28.2 kWh
65 % 75 kW 00:38:33 28.6 kWh
66 % 73 kW 00:38:55 29.0 kWh
67 % 71 kW 00:39:19 29.5 kWh
68 % 69 kW 00:39:44 29.9 kWh
69 % 66 kW 00:40:09 30.4 kWh
70 % 64 kW 00:40:35 30.8 kWh
71 % 62 kW 00:41:02 31.2 kWh
72 % 60 kW 00:41:30 31.7 kWh
73 % 57 kW 00:41:59 32.1 kWh
74 % 55 kW 00:42:30 32.6 kWh
75 % 53 kW 00:43:01 33.0 kWh
76 % 50 kW 00:43:34 33.4 kWh
77 % 48 kW 00:44:09 33.9 kWh
78 % 46 kW 00:44:45 34.3 kWh
79 % 44 kW 00:45:23 34.8 kWh
80 % 41 kW 00:46:03 35.2 kWh
81 % 39 kW 00:46:45 35.6 kWh
82 % 37 kW 00:47:30 36.1 kWh
83 % 35 kW 00:48:18 36.5 kWh
84 % 32 kW 00:49:09 37.0 kWh
85 % 30 kW 00:50:04 37.4 kWh
86 % 28 kW 00:51:02 37.8 kWh
87 % 26 kW 00:52:06 38.3 kWh
88 % 24 kW 00:53:14 38.7 kWh
89 % 22 kW 00:54:29 39.2 kWh
90 % 20 kW 00:55:52 39.6 kWh
91 % 18 kW 00:57:23 40.0 kWh
92 % 16 kW 00:59:06 40.5 kWh
93 % 13 kW 01:01:04 40.9 kWh
94 % 11 kW 01:03:21 41.4 kWh
95 % 9 kW 01:06:06 41.8 kWh
96 % 7 kW 01:09:33 42.2 kWh
97 % 5 kW 01:14:09 42.7 kWh
98 % 3 kW 01:21:03 43.1 kWh
99 % 1 kW 01:35:00 43.6 kWh
100 % 10 kW 01:40:10 44.0 kWh