Acura ZDX A-Spec AWD charging curve & performance
Below is the charging curve for Acura ZDX A-Spec AWD, illustrating the charging speed at various battery levels. Additionally, graphs for range and time provide comprehensive details on charging performance.
Charging Highlights
112.5 kWh — 112.5 kWh Ultium
Charging Performance
Advanced Metrics
Time Analysis
Range Analysis
Key Insights
Charging Speed Analysis
| SOC Range | Charger output (kW) | Total Time | Energy Added |
|---|---|---|---|
| 0-100% | 34.8 kW | 3 h 5 m 35 s | 107.5 kWh |
| 10-100% | 32.6 kW | 2 h 58 m 8 s | 96.8 kWh |
| 10-80% | 135.6 kW | 33 m 18 s | 75.2 kWh |
Range Added Per Minute by Driving Cycle
| SOC Range | EPA | WLTP | 70 mph | 120 km/h |
|---|---|---|---|---|
| 0-100% | 2.6 km (1.6 mi) | ? | 2.5 km (1.6 mi) | 2.3 km (1.4 mi) |
| 10-100% | 2.5 km (1.6 mi) | ? | 2.4 km (1.5 mi) | 2.2 km (1.4 mi) |
| 10-80% | 10.3 km (6.4 mi) | ? | 9.8 km (6.1 mi) | 9.0 km (5.6 mi) |
Charging Curve Data (0–100% SOC)
| SOC | Charger output | Total time from 0% | Energy into battery |
|---|---|---|---|
|
0 |
50 kW | 00:00:00 | 0 kWh |
|
1 |
60 kW | 00:01:14 | 1.1 kWh |
|
2 |
70 kW | 00:02:16 | 2.2 kWh |
|
3 |
80 kW | 00:03:11 | 3.2 kWh |
|
4 |
90 kW | 00:03:58 | 4.3 kWh |
|
5 |
100 kW | 00:04:41 | 5.4 kWh |
|
6 |
110 kW | 00:05:20 | 6.4 kWh |
|
7 |
120 kW | 00:05:56 | 7.5 kWh |
|
8 |
130 kW | 00:06:28 | 8.6 kWh |
|
9 |
140 kW | 00:06:58 | 9.7 kWh |
|
10 |
150 kW | 00:07:26 | 10.8 kWh |
|
11 |
152 kW | 00:07:53 | 11.8 kWh |
|
12 |
155 kW | 00:08:20 | 12.9 kWh |
|
13 |
157 kW | 00:08:46 | 14.0 kWh |
|
14 |
159 kW | 00:09:12 | 15.0 kWh |
|
15 |
162 kW | 00:09:37 | 16.1 kWh |
|
16 |
164 kW | 00:10:02 | 17.2 kWh |
|
17 |
166 kW | 00:10:27 | 18.3 kWh |
|
18 |
169 kW | 00:10:51 | 19.4 kWh |
|
19 |
171 kW | 00:11:15 | 20.4 kWh |
|
20 |
173 kW | 00:11:39 | 21.5 kWh |
|
21 |
176 kW | 00:12:02 | 22.6 kWh |
|
22 |
178 kW | 00:12:25 | 23.6 kWh |
|
23 |
180 kW | 00:12:48 | 24.7 kWh |
|
24 |
183 kW | 00:13:10 | 25.8 kWh |
|
25 |
185 kW | 00:13:33 | 26.9 kWh |
|
26 |
184 kW | 00:13:55 | 28.0 kWh |
|
27 |
184 kW | 00:14:17 | 29.0 kWh |
|
28 |
183 kW | 00:14:39 | 30.1 kWh |
|
29 |
182 kW | 00:15:01 | 31.2 kWh |
|
30 |
182 kW | 00:15:24 | 32.2 kWh |
|
31 |
181 kW | 00:15:46 | 33.3 kWh |
|
32 |
181 kW | 00:16:09 | 34.4 kWh |
|
33 |
180 kW | 00:16:31 | 35.5 kWh |
|
34 |
180 kW | 00:16:54 | 36.6 kWh |
|
35 |
176 kW | 00:17:17 | 37.6 kWh |
|
36 |
172 kW | 00:17:40 | 38.7 kWh |
|
37 |
169 kW | 00:18:04 | 39.8 kWh |
|
38 |
165 kW | 00:18:28 | 40.8 kWh |
|
39 |
161 kW | 00:18:53 | 41.9 kWh |
|
40 |
157 kW | 00:19:19 | 43.0 kWh |
|
41 |
154 kW | 00:19:45 | 44.1 kWh |
|
42 |
150 kW | 00:20:12 | 45.2 kWh |
|
43 |
146 kW | 00:20:40 | 46.2 kWh |
|
44 |
144 kW | 00:21:08 | 47.3 kWh |
|
45 |
142 kW | 00:21:36 | 48.4 kWh |
|
46 |
141 kW | 00:22:05 | 49.4 kWh |
|
47 |
139 kW | 00:22:34 | 50.5 kWh |
|
48 |
137 kW | 00:23:04 | 51.6 kWh |
|
49 |
135 kW | 00:23:34 | 52.7 kWh |
|
50 |
134 kW | 00:24:04 | 53.8 kWh |
|
51 |
133 kW | 00:24:34 | 54.8 kWh |
|
52 |
133 kW | 00:25:05 | 55.9 kWh |
|
53 |
133 kW | 00:25:36 | 57.0 kWh |
|
54 |
133 kW | 00:26:06 | 58.0 kWh |
|
55 |
133 kW | 00:26:37 | 59.1 kWh |
|
56 |
133 kW | 00:27:08 | 60.2 kWh |
|
57 |
133 kW | 00:27:38 | 61.3 kWh |
|
58 |
133 kW | 00:28:09 | 62.4 kWh |
|
59 |
133 kW | 00:28:39 | 63.4 kWh |
|
60 |
133 kW | 00:29:10 | 64.5 kWh |
|
61 |
133 kW | 00:29:41 | 65.6 kWh |
|
62 |
133 kW | 00:30:11 | 66.6 kWh |
|
63 |
131 kW | 00:30:42 | 67.7 kWh |
|
64 |
129 kW | 00:31:13 | 68.8 kWh |
|
65 |
128 kW | 00:31:45 | 69.9 kWh |
|
66 |
126 kW | 00:32:17 | 71.0 kWh |
|
67 |
124 kW | 00:32:50 | 72.0 kWh |
|
68 |
122 kW | 00:33:23 | 73.1 kWh |
|
69 |
120 kW | 00:33:57 | 74.2 kWh |
|
70 |
118 kW | 00:34:31 | 75.2 kWh |
|
71 |
117 kW | 00:35:06 | 76.3 kWh |
|
72 |
115 kW | 00:35:41 | 77.4 kWh |
|
73 |
113 kW | 00:36:17 | 78.5 kWh |
|
74 |
111 kW | 00:36:53 | 79.6 kWh |
|
75 |
109 kW | 00:37:30 | 80.6 kWh |
|
76 |
107 kW | 00:38:08 | 81.7 kWh |
|
77 |
106 kW | 00:38:46 | 82.8 kWh |
|
78 |
104 kW | 00:39:25 | 83.8 kWh |
|
79 |
102 kW | 00:40:05 | 84.9 kWh |
|
80 |
100 kW | 00:40:45 | 86.0 kWh |
|
81 |
44 kW | 00:41:42 | 87.1 kWh |
|
82 |
42 kW | 00:43:17 | 88.2 kWh |
|
83 |
39 kW | 00:44:57 | 89.2 kWh |
|
84 |
37 kW | 00:46:44 | 90.3 kWh |
|
85 |
35 kW | 00:48:37 | 91.4 kWh |
|
86 |
32 kW | 00:50:39 | 92.4 kWh |
|
87 |
30 kW | 00:52:49 | 93.5 kWh |
|
88 |
28 kW | 00:55:10 | 94.6 kWh |
|
89 |
25 kW | 00:57:43 | 95.7 kWh |
|
90 |
23 kW | 01:00:30 | 96.8 kWh |
|
91 |
21 kW | 01:03:35 | 97.8 kWh |
|
92 |
19 kW | 01:07:02 | 98.9 kWh |
|
93 |
16 kW | 01:10:57 | 100.0 kWh |
|
94 |
14 kW | 01:15:27 | 101.0 kWh |
|
95 |
12 kW | 01:20:47 | 102.1 kWh |
|
96 |
9 kW | 01:27:18 | 103.2 kWh |
|
97 |
7 kW | 01:35:41 | 104.3 kWh |
|
98 |
5 kW | 01:47:24 | 105.4 kWh |
|
99 |
2 kW | 02:06:57 | 106.4 kWh |
|
100 |
0 kW | 03:05:35 | 107.5 kWh |
Charger output is the power the charging station delivers. Energy into battery is what actually arrives: around 5% is lost to heat and conversion along the way, and charging times are calculated from that reduced figure. Dividing energy by time therefore gives a value roughly 5% below the charger output column. The 5% is an estimate — real loss varies with temperature, state of charge and the charger used. Read more about charging loss
More information
Alternative Models
In the rapidly expanding EV market, EVKX.net has identified several alternatives to the Acura ZDX A-Spec AWD that are worth considering based on features, specifications, and pricing.
Compare These Vehicles
Most sold EVs in Germany
Q1 2026 · Quarter